High Temperature Dissolved Oxygen Sensor Probe 12V Titanium

    Buy cheap High Temperature Dissolved Oxygen Sensor Probe 12V Titanium from wholesalers
     
    Buy cheap High Temperature Dissolved Oxygen Sensor Probe 12V Titanium from wholesalers
    • Buy cheap High Temperature Dissolved Oxygen Sensor Probe 12V Titanium from wholesalers
    • Buy cheap High Temperature Dissolved Oxygen Sensor Probe 12V Titanium from wholesalers
    • Buy cheap High Temperature Dissolved Oxygen Sensor Probe 12V Titanium from wholesalers

    High Temperature Dissolved Oxygen Sensor Probe 12V Titanium

    Ask Lasest Price
    Brand Name : Desun Uniwill
    Model Number : DS-380
    Price : $280.00 - $360.00/ Piece
    Payment Terms : L/C, D/A, D/P, T/T
    Supply Ability : 0~1000 pcs
    Delivery Time : 7~ 15 working days
    • Product Details
    • Company Profile

    High Temperature Dissolved Oxygen Sensor Probe 12V Titanium

    Fluorescence Analysis Dissolved Oxygen Sensor Probe 12V Titanium

    Features

    * 0-20mg/L or 0-200% saturation * 0~50 °C;
    *IP68 protection level * No film, no electrolyte, no polarization
    * No need to consume oxygen, no flow rate
    * Built-in temperature sensor, automatic temperature compensation

    Technical Parameters

    ItemParameters
    ModelDS380
    PrincipleFluorescence analysis method
    Measuring range0~20mg/L or 0-200% saturation
    Response time3 sec
    Accuracy1%
    Protection levelIP68
    InstallationSubmersible
    Temperature sensorNTC
    Temperature range0~50°C
    Temperature accuracy±0.2°C
    OutputSupport RS-485, MODBUS protocol
    Power supplyDC 6~12V, current <50mA
    SizeΦ26*155 mm
    Probe cable lengthDefault 5 m, customized 10m, 15 m and 30 m cable
    Fluorescent cap life1 year
    Maximum working pressure6bar
    product materialPOM/SS316/Titanium alloy
    Calibration methodOne or Two-point calibration
    Power consumption< 0.5 W

    Fluorescent cap daily storage

    Put it in a protective cover with a moist sponge when not in use, so that the sensor stays wet for a long time.
    If the head of the sensor's fluorescent cap is dry for a long time, it will cause drift of the measurement result, so it needs to be immersed in water for 48 hours before continuing to work.